Thermodynamics · Engineering Thermodynamics
water, steam and the property tables
Most of the world’s electricity comes from boiling water: steam drives the turbines in coal, gas, nuclear and solar-thermal plants alike. To design any of them you need to know water’s properties in every state it passes through, liquid, boiling, and vapor.
A pure substance has the same chemical composition throughout: water, nitrogen, helium, carbon dioxide. A mixture of liquid water and steam is still a pure substance, and so is air, as long as it stays a gas and its composition doesn’t change.
In the cylinder, water at 20 °C is heated under a piston that holds it at 1 atm. It warms, starts to boil at 99.97 °C, turns entirely to vapor, then keeps heating as superheated steam to 300 °C. On the diagram its state climbs the left edge of the dome, crosses it at one temperature, and leaves on the right.
This chapter is about reading that diagram and the tables behind it: the phases, saturation, the vapor dome, quality, and when a gas can be treated as ideal.
five states of water at 1 atm
Follow the water in the cylinder through five states, all at 101.325 kPa:
Boiling 1 kg at 1 atm takes 2256.5 kJ, the enthalpy of vaporization hfg (latent heat), nearly seven times the 335.1 kJ it took to warm it from 20 °C to boiling (hf rises from 83.91 to 419.06 kJ/kg). Cool it, and the same path runs backward: the steam condenses at 99.97 °C and gives that energy back.
The diagram plots v on a log scale. On a linear one the whole liquid region would be a hair-thin line against the left axis.
where water boils
At a given pressure, a pure substance boils at one temperature, its saturation temperature Tsat. At a given temperature it boils at one pressure, its saturation pressure Psat. The two are tied together by the saturation curve.
Lower the pressure and water boils cooler; raise it and it boils hotter:
| place | P (kPa) | Tsat (°C) |
|---|---|---|
| Everest summit | 31.4 | 70.18 |
| Denver | 83.4 | 94.62 |
| sea level | 101.3 | 99.97 |
| pressure cooker | 200.0 | 120.21 |
(The mountain pressures are the standard atmosphere’s at 1609 m and 8849 m; the weather moves them a few kPa.) Pasta takes longer to cook in Denver because its water can’t get above about 95 °C. A pressure cooker does the opposite, about 100 kPa above the atmosphere, so its water reaches 120 °C.
Engineers use the same physics on purpose. A steam power plant’s condenser runs at a few kPa, so steam condenses there at 40 to 50 °C and can dump its heat into a river or cooling tower. A refrigerator’s evaporator runs its refrigerant at a low pressure so that it boils below freezing (Chapter 7).
every state of water on one picture
Repeat the heating at higher pressures and join up the saturated states: the saturated-liquid states make the left side of a dome, the saturated-vapor states the right side.
The same dome appears on the P–v diagram (with isotherms instead of isobars) and on the T–s diagram of Chapter 6. Every substance has one; refrigerants are chosen for where theirs sits.
Below the triple point (0.01 °C and 0.6117 kPa for water), the liquid can’t exist at all: ice turns straight to vapor, as frost disappears on a cold, dry day without melting.
how much of the mixture is vapor
Inside the dome, temperature and pressure aren’t independent (one fixes the other), so they can’t fix the state on their own. The extra property is the quality, the mass fraction that is vapor:
x = 0 is saturated liquid, x = 1 saturated vapor. Any specific property of the mixture is a mass-weighted average of the two saturated values, which the tables list with subscript f (liquid) and g (vapor), and fg for the difference:
Rearranged, x = (v − vf)/vfg: the state sits a fraction x of the way from vf to vg, the lever rule.
Example. A rigid tank holds 2.00 kg of water at 200 kPa with quality 0.60. The table gives Tsat = 120.21 °C, vf = 0.001061, vg = 0.88568 m³/kg, hf = 504.7 and hfg = 2201.5 kJ/kg:
The other way round: 1.50 kg in a 0.500 m³ tank at 200 kPa has v = 0.3333 m³/kg, between vf and vg, so it is a mixture with x = (0.3333 − 0.001061)/0.88462 = 0.376.
Outside the dome, T and P together fix the state, and the superheated table lists v, u, h, s at each pair. When a value falls between entries, interpolate linearly. Compressed liquid is rarely tabulated in detail: use the saturated-liquid value at the same temperature (v ≈ vf@T, u ≈ uf@T).
when Pv = RT is good enough
Far from the dome, at low density, a gas obeys the ideal-gas equation of state:
Ru = 8.314 kJ/(kmol·K) is the universal gas constant and M the molar mass, so each gas has its own R: 0.287 kJ/(kg·K) for air, 0.4615 for water vapor. P and T are absolute.
Example. A car tire holds 0.025 m³ of air at 300 kPa absolute and 25 °C: m = PV/(RT) = (300)(0.025)/((0.287)(298.15)) = 0.0876 kg.
How far a real gas strays is measured by the compressibility factor:
Z = 1 for an ideal gas. Air at room conditions has Z within a fraction of a percent of 1, far above its critical temperature and far below its critical pressure. Steam in a power plant is another matter.
Example. Steam at 10 MPa and 400 °C. The ideal-gas equation gives v = RT/P = (0.4615)(673.15)/10000 = 0.03107 m³/kg. The superheated table gives 0.02644 m³/kg, so the ideal-gas value is 17.5% too high and Z = 0.851.
The rule: treat a gas as ideal when its pressure is small compared with its critical pressure or its temperature is well above its critical temperature (more than about twice). Use the tables for steam and refrigerants near their domes.