Scroll to turn the page
Electric Circuits · DC circuits
charge, current, voltage, power and the parts that use them
A circuit is a closed path for charge. A source pushes charge around it; the other elements use the energy the charge carries. Circuit analysis asks for two numbers at every element: the voltage across it and the current through it.
The figure is the smallest circuit there is: a 12 V source and a 4 Ω resistor. The source holds its top terminal 12 V above its bottom one. The resistor lets through 12 V ÷ 4 Ω = 3 A, and it turns 12 V × 3 A = 36 W into heat.
This chapter sets up the language of the rest of the course:
The course is the first circuits class of an electrical or computer engineering degree (often called Circuit Analysis or Electric Circuits I), usually taken alongside calculus and differential equations.
current is the rate charge flows
Electric charge q is measured in coulombs (C). An electron carries −e, where e = 1.602176634 × 10−19 C exactly.
Current is the rate at which charge passes a point, in amperes (A): 1 A = 1 C/s.
One ampere is 1/e ≈ 6.24 × 1018 electrons a second. The wire on the left carries 2 A, so about 1.25 × 1019 electrons cross the red slice each second.
In a metal the moving charges are electrons, which drift from − to +. By convention, though, current is counted as the flow of positive charge, the opposite way. Every arrow labeled i in this course is a reference direction: if the current really flows the other way, i comes out negative.
On the graph, mC. Its slope is the current, mA. At t = 2 s, q = 6.32 mC and i = 1.84 mA: the charge keeps rising, but more and more slowly.
the passive sign convention
Voltage is the energy per unit charge gained or lost between two points, in volts (V): 1 V = 1 J/C. It is always measured across an element, from its + terminal to its − terminal.
Power is the rate energy is used, in watts (W): 1 W = 1 J/s = 1 V·A. Whether vi is power absorbed or delivered depends on how the reference arrow and the + sign are placed, so the course fixes a rule.
The passive sign convention. When the reference current enters the element’s + terminal, p = vi is the power the element absorbs. When it enters the − terminal, use p = −vi.
The same element can do either. A phone battery absorbs power while it charges and delivers it while the phone runs: only the current’s direction changes.
the area under the power curve
Power is the rate of energy; energy is power accumulated over time.
On the left is the power drawn by a heater (hypothetical): 1.5 kW for the first hour, 0.5 kW for the second. The red area under p is the energy used; on the right, w(t) climbs with slope p:
Utilities bill in kilowatt-hours: 1 kWh = (1000 J/s)(3600 s) = 3.6 MJ, so the heater used 7.2 MJ. At a price of $0.15/kWh (hypothetical), that is $0.30.
When the power varies smoothly, integrate. An element with v = 10 V and i = 2e−t A absorbs W, and over all time
independent and dependent
An ideal voltage source holds a set voltage across its terminals whatever current flows through it. An ideal current source pushes a set current whatever voltage that takes.
On the graph each is a line in the i–v plane. The 6 V source (red) is horizontal: v = 6 V for any i. The 2 A source (blue) is vertical. Connect a load resistor R and the circuit sits where the source’s line meets the load line v = Ri. As R changes, the voltage source’s point slides along its line (the load chooses the current) and the current source’s point slides up and down its line (the load chooses the voltage).
A dependent (controlled) source, drawn as a diamond, is set by a voltage vx or current ix somewhere else in the circuit. There are four kinds:
Dependent sources model transistors and amplifiers. A bipolar transistor, for example, behaves much like a current-controlled current source with β around 50 to a few hundred.
Two connections are never allowed: ideal voltage sources of different values in parallel, and ideal current sources of different values in series. Each would contradict itself.
v = iR
A resistor opposes current. In an ideal (linear) resistor the voltage is proportional to the current, by Ohm’s law:
R is in ohms (Ω = V/A); the conductance G is in siemens (S). On the graph, each resistor is a straight line through the origin with slope G: the 2 Ω line is steepest, the 8 Ω line flattest. The current reverses when the voltage does.
Two limits come up all the time: a short circuit (R = 0, so v = 0 for any current) and an open circuit (R = ∞, so i = 0 for any voltage).
A wire’s resistance grows with its length L and shrinks with its cross-section A: R = ρL/A. Copper’s resistivity at 20 °C is 1.68 × 10−8 Ω·m, so 10 m of 1.0 mm-diameter wire has
The power a resistor absorbs follows from p = vi:
It is never negative: a resistor can only absorb power, turning it into heat.
the powers in a circuit add to zero
Energy is conserved, so at every instant the power delivered in a circuit equals the power absorbed. With the passive sign convention that becomes one equation:
The figure has a 12 V source with 4 Ω and 6 Ω resistors. Both resistors connect between the same two nodes, the top wire and the bottom wire, so each has the full 12 V across it:
Checking that the powers sum to zero is the standard test of a finished analysis: a sign error or a wrong current almost always breaks the balance.